NITRITE BORATE BASED,CORROSION INHIBITOR

High performance nitrite based closed circuit inhibitor.

Key details

Generic name NITRITE BORATE BASED,CORROSION INHIBITOR
Active matter (%) 98-100
Standard packing 25.00 Kg.PWD
Available pack sizes Borax and Nitrite corrosion inhibitor available in 5 Kg, 10, 20, 25, 50 Kg Iron and Steel corrosion inhibitor. 800-2500 ppm recommended.
Supply locations Corrosion Inhibitor Nitrite Borax based for cooling water circulation system manufacturer and supplier in Dubai, Nairobi, Mombasa, Kenya, Uganda, Mumbai, Kolkata, Visakhapatnam, Chennai, Haldai, Ennore, Paradip, Gandhidham, Surat, Canada, Dubai, Sharjah, Ajman, Abudhabi, UAE Middle East, Sohar Barka Muscat Oman

Need this product at your port or plant?

Enquire Now
Application

Engine Jacket Cooling or heating system, Chiller Water Circuit, Glycol Brine System, Hot Water or steam Circuit, Engine Coolant,Process chilling and heating system etc.

 

Engine Jacket Cooling or heating system, Chiller Water Circuit, Glycol Brine System, Hot Water or steam Circuit, Engine Coolant,Process chilling and heating system etc.

 

Using Procedure

Nitrite base Corrosion Inhibitor for Water and Glycol Brine is normally fed continuously to the re-circulating closed system by injection dosing pump of dosed to the expansion tank. The amount of Nitrite base Corrosion Inhibitor for Water and Glycol Brine required to inhibit corrosion depends on the type of system and plant operating conditions. The specific dosage rates can be specified by the testing and given parameter.

Technical Specifications

Appearance

Colourless 

Odour

Odourless 

pH

11-12 approx

Boiling Point / Boiling Range

Not determined

Melting Point/Melting Range

N/A

Flash Point N/A
Flammability Non flammable
Autoflammability N/A
Explosive Properties N/A
Oxidising Properties N/A
Vapour Pressure Not determined
Relative Density 1.18 approx
Solubility in water  Miscible
Solubility in other solvents  Not determined
Partition coefficient and N-octanol/water  ----------
Other Data None
 
Remarks

<div id="cke_pastebin">
TREATMENT                         Feature</div>
<div id="cke_pastebin">
Sodium Nitrate                       Iron and Steel corrosion inhibitor. 800-2500 ppm recommended.</div>
<div id="cke_pastebin">
Molybdate                              Slows the growth of bacteria.</div>
<div id="cke_pastebin">
Tolyltriazole                            Copper corrosion Inhibitor.</div>
<div id="cke_pastebin">
Synthetic polymer                  Prevents hard scale built up.</div>
<div id="cke_pastebin">
Borax buffer                           Corrects the water pH (Maintain pH level between 8.5 to 9.2).</div>
<div id="cke_pastebin" style="text-align: justify;">
Silicates                           A common corrosion inhibitor used by automotive antifreeze suppliers is silicates. Silicates have the disadvantage of building up an insulating layer on components and are not recommended for industrial engines. Concentration should not exceed 25 ppm.</div>

Note

Benefit :::

Zero or negligible loss of metal or corrosion Excellent heat transferability and flow rate No need of descaling closed circuit equipments Long and extended life of Water without fouling