CorroShield L01 Corrosion Inhibitor Closed Loop

Cooling Water Chemical CorroShield L01 Corrosion Inhibitor Closed Loop
Express Port Supply: 2-4 Hr Berth Delivery Across Major Indian & UAE Ports
ISO 9001:2015 Certified QA
IMPA / ISSA Marine Standard
Ready Stock 25L, 210L, IBC
Cooling Water Chemical

CorroShield L01 Corrosion Inhibitor Closed Loop

Part No. RXSOL-43-4020-032

Nitrite Based corrosion inhibitor

High performance nitrite based closed circuit inhibitor.

Key Technical Details
Part number RXSOL-43-4020-032
Generic name Nitrite Based corrosion inhibitor
Active matter (%) 50-52
Standard packing 30.00
Available pack sizes 25, 50 Ltr, 210 Ltr packing of corossion inhibitor is blend of nitrite-borate based corrosion inhibitor containing an additional organic inhibitor to protect steel, copper and other non-ferrous metals.
Supply locations Corrosion Inhibitor Nitrite based for CLOSED LOOP manufacturer and supplier in Oman, UAE Middle East, India. RXSOL Corrosion Inhibitor Nitrite based for CLOSED LOOP is most popular product among our customer and we are supplier of Corrosion Inhibitor Nitrite based for CLOSED LOOP in Mumbai, Kandla Gandhidham, Chennai, Visakhapatnam, Kolkata, Muscat, Sohar, Barka, Fujairah, Abudhabi, Dubai, Sharjah, Middle East, Canada
Application

Engine Jacket Cooling or heating system, Chiller Water Circuit, Glycol Brine System, Hot Water or steam Circuit, Engine Coolant,Process chilling and heating system etc.

Using Procedure

Nitrite base Corrosion Inhibitor for Water and Glycol Brine is normally fed continuously to the re-circulating closed system by injection dosing pump of dosed to the expansion tank. The amount of Nitrite base Corrosion Inhibitor for Water and Glycol Brine required to inhibit corrosion depends on the type of system and plant operating conditions. The specific dosage rates can be specified by the testing and given parameter.

The disadvantages of not treating the closed circuit water can be equally troubling for the system operator:-
1. Leakage in PHE and AHU due to corrosion
2. Plugging and clogging of tubes and reduced flow rate
3. Reduced heat transfer
4. Need of regular descalling that incurs shutdowns, loss of labor and time
5. Fouling of brine of chiller water

Technical Specifications

Appearance

Colourless 

Odour

Odourless 

pH

11-12 approx

Boiling Point / Boiling Range

Not determined

Melting Point/Melting Range

N/A

Flash Point N/A
Flammability Non flammable
Autoflammability N/A
Explosive Properties N/A
Oxidising Properties N/A
Vapour Pressure Not determined
Relative Density 1.18 approx
Solubility in water  Miscible
Solubility in other solvents  Not determined
Partition coefficient and N-octanol/water  ----------
Other Data None
Remarks

The disadvantages of not treating the closed circuit water can be equally troubling for the system operator:-
1. Leakage in PHE and AHU due to corrosion
2. Plugging and clogging of tubes and reduced flow rate
3. REduced heat transfer
4. Need of regular descalling that incurs shutdowns, loss of labor and time
5. Fouling of brine of chiller water

Chemical tratment removes dissolved oxygen that cause oxidation of metal to metal oxide i.e., Iron + Oxygen = Iron Oxide (Rust)

The chemical also contains a specific inhibitor to protect copper from corrosion and removes/prevents any sort of scale formation in the system.

Note

Features and Benefits of Corrosion Inhibitor Nitrite based for CLOSED LOOP :::

Zero or negligible loss of metal or corrosion Excellent heat transferability and flow rate No need of descaling closed circuit equipments Long and extended life of Water without fouling

  • Contains Corrosion inhibitors for C.S, S.S, & Cu, which helps to extend equipment life & reduce maintenance costs.
  • Contains no heavy metals compatible with antifreeze, no environmental restrictions.
  • Completely water soluble, which enhances complete system protection.
  • Contains high concentrations of active inhibitors, thus dosage rates become more cost effective.
  • Corrosion Inhibitor Nitrite based for CLOSED LOOP is most effective at pH> 8.0.
  • Corrosion Inhibitor Nitrite based for CLOSED LOOP is formulated with a synergistic blend of nitrite and other Inhibitors.
  • Contains a blend of alkalis to offer metal passivation.
  • Contains a special dye to trace system leaks & observe Inhibitor Concentration.
  • Corrosion Inhibitor Nitrite based for CLOSED LOOP contain special Corrosion Inhibitors that can tolerate moderate heat fluxes.
  • Contains Corrosion Inhibitors for soft metals (weld joints).

Need CorroShield L01 Corrosion Inhibitor Closed Loop for your operation?

Our team helps with product selection, dosage, safety data and delivery worldwide.

Request a Quote