CORROSION INHIBITOR CI 3023

RIGS Oil Field CORROSION INHIBITOR CI 3023
Express Port Supply: 2-4 Hr Berth Delivery Across Major Indian & UAE Ports
ISO 9001:2015 Certified QA
IMPA / ISSA Marine Standard
Ready Stock 25L, 210L, IBC
RIGS Oil Field

CORROSION INHIBITOR CI 3023

Part No. RXSOL-34-8165-211

Film Fomring Corrosion Inhibitor

Film-forming corrosion inhibitors work by adsorbing onto metal surfaces and forming a protective barrier that reduces contact between corrosive fluids and the underlying metal.

Key Technical Details
Part number RXSOL-34-8165-211
Generic name Film Fomring Corrosion Inhibitor
Standard packing 25.00
Available pack sizes Film forming type, corrosion inhibitor. The dosing rate of corrosion inhibitor shall be 6-12 ppm (g/m3) based on the flow rate of product being transported through the pipelines.
Supply locations RXSOL Corrosion Inhibitor KI 3939 Equivalent – Supplier India, UAE & Oman RXSOL CHEMO PHARMA INTERNATIONAL Region Website India RXSOL India UAE DUBI CHEM UAE Oman Oman Chemical Product Page: RXSOL Corrosion Inhibitor CI 3023 Corrosion Inhibitor KI 3939 Equivalent | RXSOL CI 3023 Supplier India UAE Oman RXSOL Corrosion Inhibitor CI 3023, RXSOL-81-8165-211, marketed as an alternative to KI 3939. Film-forming corrosion inhibitor for oil and gas pipelines, supplied in India, UAE and Oman. corrosion-inhibitor-ki-3939-equivalent-rxsol-ci-3023 Corrosion Inhibitor KI 3939, KI 3939 Equivalent, RXSOL CI 3023, RXSOL-81-8165-211, Oilfield Corrosion Inhibitor, Film Forming Corrosion Inhibitor, Pipeline Corrosion Inhibitor, Corrosion Inhibitor Supplier India, Corrosion Inhibitor Dubai, Corrosion Inhibitor Oman. The published RXSOL catalogue identifies CI 3023 as a KI 3939 alternative. Before supplying it as an equivalent, compare the customer's original KI 3939 TDS/SDS with the RXSOL product and validate performance under the actual operating conditions. Corrosion Inhibitor CI 2700 manufacturer supplier distributor in Mumbai, Kandla, Kolkata, Vizag, Chennai, India, Fujairah, Dubai UAE, Muscat Oman, Kenya Africa. Get the best quality of Corrosion Inhibitor CI 2700 at a competitive price from us. We have ready stock of Corrosion Inhibitor CI 2700 in India, UAE Gulf, Oman, Kenya Africa. Contact us for bulk as well as small orders.
Application

RXSOL TECHNICAL PRODUCT BULLETIN

CORROSION INHIBITOR KI 3939

Film-Forming Corrosion Inhibitor for Oil & Gas Production and Pipeline Protection

RXSOL Equivalent Product: Corrosion Inhibitor CI 3023 RXSOL Product Code: RXSOL-81-8165-211 Product Category: Oilfield Chemicals / Pipeline Corrosion Inhibitors Application: Oil & Gas Production, Hydrocarbon Pipelines and Industrial Corrosion Protection

Major Applications

Application

Purpose

Crude Oil Pipelines

Internal corrosion protection

Oil & Gas Production Lines

Control of corrosion in production fluids

Flowlines

Protection of compatible carbon steel surfaces

Gathering Pipelines

Corrosion management during fluid transportation

Production Equipment

Reduction of corrosion-related metal deterioration

Industrial Hydrocarbon Systems

Corrosion control where validated

Suitability for CO₂-containing or H₂S-containing fluids must be confirmed through representative corrosion testing. Inhibitor performance depends on fluid composition, temperature, flow conditions and metallurgy.

Using Procedure

Working Mechanism

The intended corrosion inhibition mechanism involves:

Surface Adsorption: Active inhibitor components adsorb onto compatible metal surfaces.

Protective Film Formation: A barrier film reduces exposure of the metal to corrosive components.

Corrosion Rate Reduction: The protective layer helps reduce electrochemical corrosion reactions.

Film Maintenance: Continuous injection may be required to replenish the inhibitor film under flowing conditions.

Recommended Dosage

Application

Preliminary Dosage

Continuous Pipeline Injection

6–12 ppm, supplier-published range

High-Corrosion Systems

Determine through laboratory and field trials

Initial Film Establishment

Site-specific treatment programme

Batch Treatment

Subject to system design and validation

Example: For a pipeline carrying 100 m³/hour of fluid, a treatment rate of 10 ppm by mass corresponds to approximately 1 kg/hour of inhibitor if the treated fluid density is assumed to be 1,000 kg/m³.

For other fluid densities, the required inhibitor mass flow changes accordingly.

The actual injection volume also depends on the inhibitor's density.

Technical Specifications

Technical Specifications

 

Parameter

Description

Product Name

Corrosion Inhibitor CI 3023

Equivalent Reference

KI 3939

RXSOL Code

RXSOL-81-8165-211

Product Type

Film-forming corrosion inhibitor

Appearance

To be confirmed from batch specification

Chemical Composition

Proprietary / not publicly confirmed

Solubility / Dispersibility

To be verified in the actual process fluid

Density

To be confirmed

pH

To be confirmed, where applicable

Flash Point

To be confirmed

Main Function

Internal corrosion inhibition

Application Method

Controlled chemical injection

Published Dosage

6–12 ppm, subject to field validation

The published RXSOL product listing specifies a dosage of 6–12 ppm (g/m³) based on the transported fluid flow rate. This should be treated as a supplier-stated starting range rather than a guaranteed effective dosage.

Key Features & Benefits

  • Film-forming corrosion inhibition technology.

  • Intended for internal corrosion control in oil and gas pipelines.

  • Helps reduce corrosion caused by contact with corrosive production fluids.

  • Suitable for evaluation in continuous chemical injection programmes.

  • Helps protect compatible carbon steel pipelines and production equipment.

  • Supports preventive maintenance and asset integrity programmes.

  • Can reduce corrosion-related equipment deterioration when properly selected and dosed.

  • Applicable to oilfield chemical treatment programmes.

Remarks

Performance Evaluation

Recommended tests include:

  • Corrosion coupon weight-loss testing.

  • Electrochemical corrosion testing.

  • Compatibility with crude oil and produced water.

  • Emulsion tendency assessment.

  • Thermal stability testing.

  • Film persistency testing.

  • Dynamic flow-loop testing where appropriate.

  • Compatibility with demulsifiers, scale inhibitors and other production chemicals.

Storage & Handling

Store in tightly closed, properly labelled containers in a cool, dry, well-ventilated location.

Use appropriate chemical-resistant gloves, eye protection and protective clothing.

Follow the finished-product SDS for handling, transport classification, fire precautions and spill response.

Packing

Product Code: RXSOL-81-8165-211

Industrial drum and bulk packing availability should be confirmed when requesting a quotation.

Note

Recommended Application Procedure

  1. Analyse the production fluid, including water cut, salinity, dissolved gases and other corrosive constituents.

  2. Confirm pipeline metallurgy and operating temperature.

  3. Select a suitable chemical injection point.

  4. Establish the preliminary dosage through laboratory testing.

  5. Inject continuously using a calibrated chemical dosing pump.

  6. Monitor corrosion performance using coupons, electrical resistance probes or other approved techniques.

  7. Adjust the injection rate according to measured corrosion performance.

Need CORROSION INHIBITOR CI 3023 for your operation?

Our team helps with product selection, dosage, safety data and delivery worldwide.

Request a Quote