Multi Functional Boiler Treatment
Part No. RXSOL-42-5001-025
multi-functional liquid reagent for the treatment of steam production systems
Highly effective multi-functional liquid reagent for the treatment of steam production systems and heating systems operating on softened water.
Key details
| Part number | RXSOL-42-5001-025 |
|---|---|
| Generic name | multi-functional liquid reagent for the treatment of steam production systems |
| Active matter (%) | 54-60 |
| Standard packing | 25.00 Ltr. |
| Available pack sizes | ONE SHOT Boiler water treatment chemical products to control scale and corrosion inhibitors, oxygen scavengers, and sludge conditioners available in 25, 50, 210 Ltr HMHDPE Barrel. |
| Supply locations | Boiler water treatment speacialized chemical products One Shot Universal Liquitreat Exporter, manufacturer, supplier in Mumbai, Gandhidham - Kandla, Mundra, Sikka, Surat, Kolkata - Haldia, Buz Buj, Paradip, Visakhapatnam - Gangavaram, Fujairah, Dubai, Sharjah, Abu Dhabi, Ruwi Barka Muscat Sohar, Oman, Sudan, Yemen, Nairobi Kenya |
Need this product at your port or plant?
Enquire Now<div id="cke_pastebin" style="text-align: justify;">
<span style="font-size:14px;">RXSOL-42-5001-025 contains an antiscalant (phosphate-polymer composition), a mixture of complexones, a pH correction reagent, an oxygen reducer and neutralizing amines. A specially selected composition of phosphates and polymers effectively prevents the formation of deposits throughout the steam production system, preventing the formation of hardness crystals and dispersing suspended particles and iron. The action of polymers is enhanced by complexons, which also form complexes with metal cations in the makeup water and provide online cleaning of the system. The reagent contains components for correcting the pH of feed water.</span></div>
<div id="cke_pastebin" style="text-align: justify;">
</div>
<p style="text-align: justify">
The dosage rate is dependent on bioler operating condition, feed 2-3 ltrs of <span style="font-size: 14px;">RXSOL-42-5001-025</span><strong> </strong>solution for per thousand ltr of bioler water then control the system by periodic Alkalinity test procedure. If p-Alkalinity is below 200 ppm increase the ratio of RXSOL BWT 5001 solution. If p-Alkalinity is above 400 ppm reduce the concentration of <span style="font-size: 14px;">RXSOL-42-5001-025</span><strong> </strong>solution by dilution with water. <span style="font-size: 14px;">RXSOL-42-5001-025</span><strong> </strong>is strongly alkaline.<span style="font-size: 14px;">RXSOL-42-5001-025</span><strong> </strong> is best applied heat or diluted with any convenient strength on a continuous basis using a suitable chemicals pump. The product should be applied to the boiler feed tank or feed line to ensure adequate mixing.</p>
<div id="cke_pastebin" style="text-align: justify;">
<span style="font-size:14px;">The oxygen reducer present in RXSOL-42-5001-025 effectively binds oxygen dissolved in the make-up water, thereby protecting the equipment from corrosion. Additional protection of lines from corrosion is provided by the presence of neutralizing and film-forming amines in the product, which increase the pH of the water.</span></div>
<div id="cke_pastebin">
</div>
<p>
Control is by simple boiler water tests or <span style="font-size: 14px"><strong>RX CLEANSERS</strong></span> can provide a suitable test kits for this purpose.</p>
<p>
Used in low pressure and auxillary boilers</p>
<p>
<strong><span style="font-size: 14px">:::::::::::::::::::::Alkalinity TEST FOR BOILER & COOLING WATER ::::::::::::::::::::::::</span><br />
<br />
<u>REAGENT & APPARATUS</u></strong> :<br />
Reagent: RXSOL TK 7 , TK 8 , TK 9 , . Apparatus : TEST TUBE , Titrator or DROPPER<br />
<br />
<strong><u>PROCEDURE for p-ALKALINITY test ( STEP WISE )</u></strong><u>:</u></p>
<ol>
<li>
Measure 10 ml of SAMPLE WATER in graduated TEST TUBE / CYLINDER</li>
<li>
Add 1-2 drops of <strong>RXSOL TK7</strong> and mix with the stirring rod , If sample turns red / PINK ( which indicates presence of p-Alkalinity ) then follows 3<sup>rd</sup> step otherwise if sample remains colourless ( Record p-Alkalinity = 0 ) .</li>
<li>
Add <strong>RXSOL TK9 </strong>drop by drop ( by counting ) , mixing with the stirring rod until colour just disappears. Each drop is equivalent to 25 ppm of p-Alkalinity , expressed as CaCO<sub>3 </sub></li>
</ol>
<p>
RESULT : Each DROPS is equivalent to 25 PPM of Alkalinity .<br />
<br />
NOTE : p-Alkalinity VALUE = 25 X ( Total Number of DROPS of TK9 , during 3<sup>rd</sup>step )</p>
<p>
</p>
<p>
<strong><u>PROCEDURE for p-ALKALINITY & TOTAL ALKALINITY ( STEP WISE )</u></strong><u>:</u></p>
<ol>
<li>
Measure 10 ml of SAMPLE WATER in graduated TEST TUBE / CYLINDER</li>
<li>
Add 1-2 drops of <strong>RXSOL TK7</strong> and mix with the stirring rod , If sample turns red / PINK ( which indicates presence of p-Alkalinity ) then follows 3<sup>rd</sup> step otherwise if sample remains colourless ( Record p-Alkalinity = 0 ) then proceed to STEP- 4.</li>
<li>
Add <strong>RXSOL TK9 </strong>drop by drop ( by counting ) , mixing with the stirring rod until colour just disappears. Each drop is equivalent to 15 ppm of p-Alkalinity , expressed as CaCO<sub>3 </sub></li>
<li>
Add 2-3 drops of <strong>RXSOL TK8</strong> and mix with stirring rod , the sample will turn to BLUISH-GREEN .</li>
<li>
Add<strong>RXSOL TK9 </strong>carefully by counting drop by drop and mixing throughly until a light reddish pink colour develop.</li>
</ol>
<p>
RESULT : Each DROPS is equivalent to 25 PPM of Alkalinity .</p>
<p>
NOTE : p-Alkalinity ppm CaCO<sub>3</sub>VALUE ( A ) = 25 X ( Total Number of DROPS of TK9 , during 3<sup>rd</sup>step )</p>
<p>
Total Alkalinity ppm CaCO<sub>3</sub>VALUE = A + { 25 X ( Total Number of DROPS of TK9 , during 5<sup>th</sup> step )}</p>
<p>
</p>
<p>
</p>
<p>
</p>
<table border="1" cellpadding="0" cellspacing="0" style="width: 642px; height: 651px">
<tbody>
<tr>
<td style="width: 638px">
<p>
NUMBER OF DROPS OF TK9 p-Alkalinity as CaCO<sub>3</sub> </p>
<p>
1 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>25<br />
2 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>50</p>
<p>
3 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 75<br />
4 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 100</p>
<p>
5 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> > 125<br />
10 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> > 250</p>
<p>
20 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> > 500<br />
30>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> >750</p>
<p>
40 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> 1000<br />
</p>
<p>
Optimum Result : p-Alkalinity level is between 100 to 150 PPM is suggested.<br />
<br />
if p-Alkalinity level is more then 150 ppm then level should be reduced by increased BLOW DOWN process with immediate effect. </p>
<p>
For Below 50 ppm , Dose ½ Ltrs of RXSOL-50-5001-025 for 1000 Ltrs of BOILER WATER , to maintain p-Alkalinity level 100 ppm.</p>
<p>
Refill pack : REPLACEMENTS </p>
<p>
TK7 : ECONOMIC PACK ( 100 / 200 / 500 ml ) available</p>
<p>
TK8 : ECONOMIC PACK ( 100 / 200 / 500 ml ) available</p>
<p>
TK9 : ECONOMIC PACK ( 100 / 200 / 500 ml ) available</p>
</td>
</tr>
</tbody>
</table>
<p>
<span style="text-align: justify;">Boiler Water Treatment products</span></p>
<p style="text-align: justify;">
CHARACTERISTIC :</p>
<ul>
<li>
Convenient liquid treatment, which provides the basic alkalinity on which successful water treatment depends.</li>
<li>
Provides optimum conditions for hardness control to function.</li>
<li>
Neutralizes acid conditions.</li>
<li>
Will assist in keeping silica in suspension.</li>
<li>
Simple test to determine level of treatment.</li>
<li>
Can be used in boilers of all pressures.</li>
<li>
Can be used as a neutralizer after acid cleaning operations</li>
<li>
Suitable for use with all auxiliary boilers; waste heat units; economizers, package boilers, smoke and water tube boilers.</li>
<li>
Dispersant action suspends sludge and sediment particles for efficient blow down.</li>
<li>
Oxygen scavenging for optimum protection.</li>
<li>
Protects boiler, steam lines, condensate lines and feed water lines from corrosion.</li>
<li>
Fast action due to catalyst.</li>
<li>
Simple test to determine level of treatment.</li>
</ul>
<p style="text-align: justify;">
<span style="font-size: 14px;">RXSOL-42-5001-025 Boiler Water treatment specialized is a well - balanced blend for boiler water treatment products, Resulting Multi Functional Boiler Treatment including</span> <strong><span style="font-size: 16px;">scale and corrosion control</span></strong> <span style="font-size: 14px;">by one shot operation. A one-step treatment to control the formation of rust and scale in low pressure and auxillary boilers with working pressure up to 20 bars.</span></p>
<p style="text-align: justify;">
<span style="font-size: 14px;">The stability of the added polymers are very useful for water treatment processes. Such polymers with low molecular weights cannot only inhibit calcium, magnesium, and silica scale in cooling towers and boilers, but also help corrosion control by dispersing iron oxide. </span></p>
<p>
<br />
<strong>Basic Boiler System Schematic</strong></p>
<p>
Below is a summary of problems associated with the common impurities in water and solutions to each problem.</p>
<p>
<strong>List Of Problems Caused By Impurities In Water</strong></p>
<table border="0" cellpadding="0" cellspacing="0">
<tbody>
<tr>
<td style="width: 219px; height: 33px;">
<p align="center">
<strong>Impurity (Chemical Formula)</strong></p>
</td>
<td style="width: 219px; height: 33px;">
<p align="center">
<strong>Problems</strong></p>
</td>
<td style="width: 219px; height: 33px;">
<p align="center">
<strong>Common Chemical Treatment Methods</strong></p>
</td>
</tr>
<tr>
<td style="width: 219px; height: 45px;">
<p>
Alkalinity (HCO<sub>3</sub>-, CO<sub>3</sub><sup>2- </sup>and CaCO<sub>3</sub>)</p>
</td>
<td style="width: 219px; height: 45px;">
<p style="text-align: justify;">
Carryover of feedwater into steam, produce CO<sub>2 </sub>in steam leading to formation of carbonic acid (acid attack)</p>
</td>
<td style="width: 219px; height: 45px;">
<p style="text-align: justify;">
Neutralizing amines, filming amines, combination of both, and lime-soda.</p>
</td>
</tr>
<tr>
<td style="width: 219px; height: 31px;">
<p>
Hardness (calcium and magnesium salts, CaCO<sub>3</sub>)</p>
</td>
<td style="width: 219px; height: 31px;">
<p style="text-align: justify;">
Primary source of scale in heat exchange equipment</p>
</td>
<td style="width: 219px; height: 31px;">
<p style="text-align: justify;">
Lime softening, phosphate, chelates and polymers</p>
</td>
</tr>
<tr>
<td style="width: 219px; height: 17px;">
<p>
Iron (Fe<sup>3+ </sup>and Fe<sup>2+</sup>)</p>
</td>
<td style="width: 219px; height: 17px;">
<p style="text-align: justify;">
Causes boiler and water line deposits</p>
</td>
<td style="width: 219px; height: 17px;">
<p style="text-align: justify;">
Phosphate, chelates and polymers</p>
</td>
</tr>
<tr>
<td style="width: 219px; height: 30px;">
<p>
Oxygen (O<sub>2</sub>)</p>
</td>
<td style="width: 219px; height: 30px;">
<p style="text-align: justify;">
Corrosion of water lines, boiler, return lines, heat exchanger equipments, etc. (oxygen attack)</p>
</td>
<td style="width: 219px; height: 30px;">
<p style="text-align: justify;">
Oxygen scavengers, filming amines and deaeration</p>
</td>
</tr>
<tr>
<td style="width: 219px; height: 30px;">
<p>
pH</p>
</td>
<td style="width: 219px; height: 30px;">
<p style="text-align: justify;">
Corrosion occurs when pH drops below 8.5</p>
</td>
<td style="width: 219px; height: 30px;">
<p style="text-align: justify;">
pH can be lowered by addition of acids and increased by addition of alkalies</p>
</td>
</tr>
<tr>
<td style="width: 219px; height: 17px;">
<p>
Hydrogen Sulfide (H<sub>2</sub>S)</p>
</td>
<td style="width: 219px; height: 17px;">
<p>
Corrosion</p>
</td>
<td style="width: 219px; height: 17px;">
<p>
Chlorination</p>
</td>
</tr>
<tr>
<td style="width: 219px; height: 17px;">
<p>
Silica (SiO<sub>2</sub>)</p>
</td>
<td style="width: 219px; height: 17px;">
<p style="text-align: justify;">
Scale in boilers and cooling water systems</p>
</td>
<td style="width: 219px; height: 17px;">
<p>
Lime softening</p>
</td>
</tr>
</tbody>
</table>
<div id="cke_pastebin">
More about RXSOL NEUTRALIZER for Boiler System RXSOL-42-5001-025</div>
<div id="cke_pastebin">
RXSOL-42-5001-025 is a highly effective multi-functional liquid reagent for the treatment of steam production systems and heating systems operating on softened water.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
Product Mecahnism : </div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin" style="text-align: justify;">
RXSOL-42-5001-025 contains an antiscalant (phosphate-polymer composition), a mixture of complexones, a pH correction reagent, an oxygen reducer and neutralizing amines. A specially selected composition of phosphates and polymers effectively prevents the formation of deposits throughout the steam production system, preventing the formation of hardness crystals and dispersing suspended particles and iron. The action of polymers is enhanced by complexons, which also form complexes with metal cations in the makeup water and provide online cleaning of the system. The reagent contains components for correcting the pH of feed water.</div>
<div id="cke_pastebin" style="text-align: justify;">
</div>
<div id="cke_pastebin" style="text-align: justify;">
The oxygen reducer present in RXSOL-42-5001-025 effectively binds oxygen dissolved in the make-up water, thereby protecting the equipment from corrosion. Additional protection of lines from corrosion is provided by the presence of neutralizing and film-forming amines in the product, which increase the pH of the water.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
Appearance: brown liquid</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
Density (kg/m3): 1100</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
pH: 12.6</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
Freezing point: 0°C</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
The data given represents typical values for the product and cannot be regarded as technical specifications.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
Dosing</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin" style="text-align: justify;">
RXSOL-42-5001-025 is dosed directly into water. The best dosing point is below the surface of the water in the deaerator tank; Stainless steel materials should be used for dosing. The product should be diluted (if necessary) with softened water or condensate. The dosage depends on the chemical composition of the makeup water, as well as on the operating conditions of the boiler. Range of working dosages: 10-100 g/m3.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
Multifunctional reagent for boiler water</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
Precautionary measures</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin" style="text-align: justify;">
Protective gloves and safety glasses must be worn. In case of contact, rinse immediately with plenty of water. In case of contact with eyes, consult a doctor. If product leaks, contain it with sand or other inert material and sweep it away. Then rinse the surface with plenty of water.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
Before use, please read the Safety Data Sheet for the product.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
Important information</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin" style="text-align: justify;">
The RXSOL company has Safety Data Sheets for all chemical products it produces. Safety data sheets contain information about the safe use of the relevant product for the health of workers. Before using Solenis products in production, management and employees of your enterprise should familiarize themselves with these safety data sheets.</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
Package</div>
<div id="cke_pastebin">
</div>
<div id="cke_pastebin">
RXSOL-42-5001-025 is available in 25 and 225 kg plastic containers and 1100 kg sealed containers.</div>
Need Multi Functional Boiler Treatment for your operation?
Our team helps with product selection, dosage, safety data and delivery worldwide.