One Shot Universal Liquitreat 100

Deck cabin galley Maintenance-25

One Shot Universal Liquitreat 100

BOILER scale and corrosion control by one shot operation

A one-step and one SHOT treatment to control the formation of rust and scale in boilers. Contains alkaline compounds, scale and corrosion inhibitors, oxygen scavengers and sludge conditioners

Key details

Generic name BOILER scale and corrosion control by one shot operation
Active matter (%) 54-60
Standard packing 25.00 Ltr.
Available pack sizes ONE SHOT Boiler water treatment chemical products to control scale and corrosion inhibitors, oxygen scavengers, and sludge conditioners available in 25, 50, 210 Ltr HMHDPE Barrel.
Supply locations Boiler water treatment speacialized chemical products One Shot Universal Liquitreat Exporter, manufacturer, supplier in Mumbai, Gandhidham - Kandla, Mundra, Sikka, Surat, Kolkata - Haldia, Buz Buj, Paradip, Visakhapatnam - Gangavaram, Fujairah, Dubai, Sharjah, Abu Dhabi, Ruwi Barka Muscat Sohar, Oman, Sudan, Yemen, Nairobi Kenya

Need this product at your port or plant?

Enquire Now
Application

The dosage rate is dependent on bioler operating condition, feed 2-3 ltrs of RXSOL-50-5001-025 solution for per thousand ltr of bioler water then control the system by periodic Alkalinity test procedure. If p-Alkalinity is below 200 ppm increase the ratio of RXSOL BWT 5001 solution. If p-Alkalinity is above 400 ppm reduce the concentration of RXSOL-50-5001-025 solution by dilution with water. RXSOL-50-5001-025 is strongly alkaline.RXSOL-50-5001-025  is best applied heat or diluted with any convenient strength on a continuous basis using a suitable chemicals pump. The product should be applied to the boiler feed tank or feed line to ensure adequate mixing.

Using Procedure

Control is by simple  boiler water tests or RX CLEANSERS  can provide a suitable test  kits for this purpose.

Used in low pressure and auxillary boilers

:::::::::::::::::::::Alkalinity  TEST FOR BOILER & COOLING WATER ::::::::::::::::::::::::

REAGENT & APPARATUS :
Reagent:  RXSOL TK 7 , TK 8 , TK 9 , . Apparatus : TEST TUBE , Titrator or DROPPER

PROCEDURE for p-ALKALINITY  test ( STEP WISE ):

  1. Measure 10 ml of SAMPLE WATER in graduated TEST TUBE / CYLINDER
  2. Add 1-2 drops of  RXSOL TK7 and mix with the stirring rod , If  sample turns red / PINK ( which indicates presence of p-Alkalinity ) then follows 3rd step otherwise if sample remains colourless ( Record p-Alkalinity = 0 ) .
  3. Add RXSOL TK9  drop by drop ( by counting ) , mixing with the stirring rod until colour just disappears. Each drop is equivalent to 25 ppm of p-Alkalinity , expressed as CaCO3

RESULT  : Each DROPS is equivalent to  25 PPM of Alkalinity .

NOTE :    p-Alkalinity VALUE  =  25 X ( Total Number of DROPS of TK9 , during 3rdstep  )

        

PROCEDURE for p-ALKALINITY  & TOTAL ALKALINITY ( STEP WISE ):

  1. Measure 10 ml of SAMPLE WATER in graduated TEST TUBE / CYLINDER
  2. Add 1-2 drops of  RXSOL TK7 and mix with the stirring rod , If  sample turns red / PINK ( which indicates presence of p-Alkalinity ) then follows 3rd step otherwise if sample remains colourless ( Record p-Alkalinity = 0 ) then proceed to STEP- 4.
  3. Add RXSOL TK9  drop by drop ( by counting ) , mixing with the stirring rod until colour just disappears. Each drop is equivalent to 15 ppm of p-Alkalinity , expressed as CaCO3
  4. Add 2-3 drops of RXSOL TK8 and mix with stirring rod , the sample will turn to BLUISH-GREEN .
  5. AddRXSOL TK9 carefully by counting drop by drop and mixing throughly until a light reddish  pink  colour develop.

RESULT  : Each DROPS is equivalent to 25 PPM of Alkalinity .

NOTE :    p-Alkalinity ppm CaCO3VALUE ( A )  =  25 X ( Total Number of DROPS of TK9 , during 3rdstep  )

Total Alkalinity ppm CaCO3VALUE  =  A +  { 25 X ( Total Number of DROPS of TK9 , during 5th step  )}

 

 

 

NUMBER OF DROPS OF TK9                                                                                     p-Alkalinity as CaCO3                                

                        1 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>25
                        2 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>50

                        3 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>  75
                        4 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>  100

                        5 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> > 125
                       10 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> >  250

                       20 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> >  500
                       30>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>> >750

                       40 >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>  1000
 

Optimum Result    :   p-Alkalinity  level  is between 100 to  150 PPM is suggested.

 if  p-Alkalinity level is more then 150 ppm then level should be reduced by increased BLOW DOWN process with immediate effect.   

For Below  50 ppm  , Dose ½ Ltrs of RXSOL-50-5001-025 for 1000 Ltrs of  BOILER WATER , to maintain p-Alkalinity level 100 ppm.

Refill pack : REPLACEMENTS  

TK7   : ECONOMIC PACK ( 100 / 200 / 500 ml ) available

TK8   : ECONOMIC PACK ( 100 / 200 / 500 ml ) available

TK9   : ECONOMIC PACK ( 100 / 200 / 500 ml ) available

Technical Specifications

Boiler Water Treatment products

CHARACTERISTIC :

  • Convenient liquid treatment, which provides the basic alkalinity on which successful water treatment depends.
  • Provides optimum conditions for hardness control to function.
  • Neutralizes acid conditions.
  • Will assist in keeping silica in suspension.
  • Simple test to determine level of treatment.
  • Can be used in boilers of all pressures.
  • Can be used as a neutralizer after acid cleaning operations
  • Suitable for use with all auxiliary boilers; waste heat units; economizers, package boilers, smoke and water tube boilers.
  • Dispersant action suspends sludge and sediment particles for efficient blow down.
  • Oxygen scavenging for optimum protection.
  • Protects boiler, steam lines, condensate lines and feed water lines from corrosion.
  • Fast action due to catalyst.
  • Simple test to determine level of treatment.
Remarks

<p>
<strong>Basic Boiler System Schematic</strong></p>
<p>
Below is a summary of problems associated with the common impurities in water and solutions to each problem.</p>
<p>
<strong>List Of Problems Caused By Impurities In Water</strong></p>
<table border="1" cellpadding="0" cellspacing="0">
<tbody>
<tr>
<td style="width: 219px; height: 33px;">
<p align="center">
<strong>Impurity (Chemical Formula)</strong></p>
</td>
<td style="width: 219px; height: 33px;">
<p align="center">
<strong>Problems</strong></p>
</td>
<td style="width: 219px; height: 33px;">
<p align="center">
<strong>Common Chemical Treatment Methods</strong></p>
</td>
</tr>
<tr>
<td style="width: 219px; height: 45px;">
<p>
Alkalinity (HCO<sub>3</sub>-, CO<sub>3</sub><sup>2- </sup>and CaCO<sub>3</sub>)</p>
</td>
<td style="width: 219px; height: 45px;">
<p style="text-align: justify;">
Carryover of feedwater into steam, produce CO<sub>2 </sub>in steam leading to formation of carbonic acid (acid attack)</p>
</td>
<td style="width: 219px; height: 45px;">
<p style="text-align: justify;">
Neutralizing amines, filming amines, combination of both, and lime-soda.</p>
</td>
</tr>
<tr>
<td style="width: 219px; height: 31px;">
<p>
Hardness (calcium and magnesium salts, CaCO<sub>3</sub>)</p>
</td>
<td style="width: 219px; height: 31px;">
<p style="text-align: justify;">
Primary source of scale in heat exchange equipment</p>
</td>
<td style="width: 219px; height: 31px;">
<p style="text-align: justify;">
Lime softening, phosphate, chelates and polymers</p>
</td>
</tr>
<tr>
<td style="width: 219px; height: 17px;">
<p>
Iron (Fe<sup>3+ </sup>and Fe<sup>2+</sup>)</p>
</td>
<td style="width: 219px; height: 17px;">
<p style="text-align: justify;">
Causes boiler and water line deposits</p>
</td>
<td style="width: 219px; height: 17px;">
<p style="text-align: justify;">
Phosphate, chelates and polymers</p>
</td>
</tr>
<tr>
<td style="width: 219px; height: 30px;">
<p>
Oxygen (O<sub>2</sub>)</p>
</td>
<td style="width: 219px; height: 30px;">
<p style="text-align: justify;">
Corrosion of water lines, boiler, return lines, heat exchanger equipments, etc. (oxygen attack)</p>
</td>
<td style="width: 219px; height: 30px;">
<p style="text-align: justify;">
Oxygen scavengers, filming amines and deaeration</p>
</td>
</tr>
<tr>
<td style="width: 219px; height: 30px;">
<p>
pH</p>
</td>
<td style="width: 219px; height: 30px;">
<p style="text-align: justify;">
Corrosion occurs when pH drops below 8.5</p>
</td>
<td style="width: 219px; height: 30px;">
<p style="text-align: justify;">
pH can be lowered by addition of acids and increased by addition of alkalies</p>
</td>
</tr>
<tr>
<td style="width: 219px; height: 17px;">
<p>
Hydrogen Sulfide (H<sub>2</sub>S)</p>
</td>
<td style="width: 219px; height: 17px;">
<p>
Corrosion</p>
</td>
<td style="width: 219px; height: 17px;">
<p>
Chlorination</p>
</td>
</tr>
<tr>
<td style="width: 219px; height: 17px;">
<p>
Silica (SiO<sub>2</sub>)</p>
</td>
<td style="width: 219px; height: 17px;">
<p style="text-align: justify;">
Scale in boilers and cooling water systems</p>
</td>
<td style="width: 219px; height: 17px;">
<p>
Lime softening</p>
</td>
</tr>
</tbody>
</table>

Related products

From our blog

Need One Shot Universal Liquitreat 100 for your operation?

Our team helps with product selection, dosage, safety data and delivery worldwide.

Request a Quote